Connect with confidence

SET UP
THE TEST.

Choose from 32 equipment and test guides covering electrical, fuel, mechanical, cooling and air systems.

Multimeter workflow

  1. Select the correct function: DC volts, resistance, frequency or current.
  2. Connect the black lead to COM and the red lead to the fused input required by the function.
  3. Back-probe the circuit without spreading terminals; reference the specified ground.
  4. Measure at rest, during operation and under load, recording min/max values.

Before you measure

  • Never measure resistance on a powered circuit.
  • Use a fused current input and verify its rating before series testing.
  • Compare supply and ground at the component, not only at the battery.

Electrical & oscilloscope tests

Power-Side Voltage Drop

Locate resistance in a loaded low-voltage power path. This does not test a circuit’s capacity while it is switched off.

Read guide →

Loaded Ground Voltage Drop

Check whether a low-voltage ground path carries operating current without excessive loss.

Read guide →

5 V Reference Circuit

Check a regulated sensor supply and identify shared-reference faults. A correct reference alone does not prove the sensor works.

Read guide →

Parasitic Draw — Current Clamp

Measure key-off current and sleep behavior without disconnecting the battery. One short observation cannot rule out an intermittent wake-up.

Read guide →

Starter Current and Cranking Voltage

Compare starter demand, battery voltage and cranking behavior on conventional low-voltage starter systems.

Read guide →

Alternator Ripple

Inspect the repeating AC component on a conventional alternator’s DC output. Ripple alone does not identify every charging fault.

Read guide →

Hall-Effect Digital Signal

Check a powered switching sensor’s supply, ground and output. This guide covers a digital Hall implementation, not every Hall sensor.

Read guide →

Variable-Reluctance Signal

Evaluate a passive inductive speed/position sensor during target movement.

Read guide →

Solenoid Current Ramp

Compare electrical current buildup with a solenoid’s command. Electrical evidence alone does not prove correct fluid flow or mechanical output.

Read guide →

Relative Compression — Starter Current

Screen for unequal cylinder loading during cranking. This compares cylinders; it does not measure absolute compression or prove all cylinders are healthy.

Read guide →

CAN Resistance and Termination

Check termination and wiring on a confirmed two-terminator high-speed CAN segment. This does not verify communication quality.

Read guide →

CAN Signal Quality — High-Speed Bus

Inspect high-speed CAN physical signaling. A plausible voltage pattern does not prove message content or module function.

Read guide →

Fuel-system tests

Mechanical tests

Cooling & air-system tests