Safety / OCS

OCCUPANT CLASSIFICATION SENSOR

Estimates seat occupancy and loading for restraint deployment decisions.

SENSOR GUIDE59/86

Identify the circuit first

ONE NAME.
DIFFERENT SIGNALS.

Pin count is a clue, not proof. Confirm the exact architecture before resistance testing, applying voltage or judging the waveform.

TYPE 01CONSTRUCTION VARIANT

Pressure mat / bladder

Confirm wiring, pin count and service information before testing.

Seat loading changes pressure or resistance measured by the restraint module.

Reading the signal

Good waveform

Compare the measured signal with the specified input or command under the same operating conditions. Levels, timing and repeatability should match the installed design and a suitable verified reference. There is no universal waveform or scale for every version of this component.

Faulty waveform

An unexplained dropout, missing response, excessive noise or mismatch between command and feedback warrants further testing. First rule out a changed physical condition, incorrect probe reference, supply loss and an unsuitable scope setting; an unusual trace alone does not identify a failed component.

TYPE-SPECIFIC TESTS

+ Use scan classification data and approved simulators; never probe an inflator circuit.

+ Verify the specified supply, ground, bias or termination before judging the signal.

+ Repeat the test through the complete operating range.

EXPECTED

✓ Output matches this construction type

✓ Stable levels and repeatable response

✓ Agreement with related scan data

COMMON FAULTS

— Incorrect test method for the sensor type

— Supply, ground or signal-circuit fault

— Installation, target or calibration concern

TYPE 02CONSTRUCTION VARIANT

Strain-gauge seat frame

Confirm wiring, pin count and service information before testing.

Load cells measure deformation at seat mounting points.

Reading the signal

Good waveform

Compare the measured signal with the specified input or command under the same operating conditions. Levels, timing and repeatability should match the installed design and a suitable verified reference. There is no universal waveform or scale for every version of this component.

Faulty waveform

An unexplained dropout, missing response, excessive noise or mismatch between command and feedback warrants further testing. First rule out a changed physical condition, incorrect probe reference, supply loss and an unsuitable scope setting; an unusual trace alone does not identify a failed component.

TYPE-SPECIFIC TESTS

+ Inspect seat mounting and wiring; perform zero calibration with the seat empty.

+ Verify the specified supply, ground, bias or termination before judging the signal.

+ Repeat the test through the complete operating range.

EXPECTED

✓ Output matches this construction type

✓ Stable levels and repeatable response

✓ Agreement with related scan data

COMMON FAULTS

— Incorrect test method for the sensor type

— Supply, ground or signal-circuit fault

— Installation, target or calibration concern

TYPE 03CONSTRUCTION VARIANT

Capacitive / integrated module

Confirm wiring, pin count and service information before testing.

Electrodes and local processing classify occupant presence.

Reading the signal

Good waveform

Compare the measured signal with the specified input or command under the same operating conditions. Levels, timing and repeatability should match the installed design and a suitable verified reference. There is no universal waveform or scale for every version of this component.

Faulty waveform

An unexplained dropout, missing response, excessive noise or mismatch between command and feedback warrants further testing. First rule out a changed physical condition, incorrect probe reference, supply loss and an unsuitable scope setting; an unusual trace alone does not identify a failed component.

TYPE-SPECIFIC TESTS

+ Verify power, communication, seat trim condition and OEM calibration.

+ Verify the specified supply, ground, bias or termination before judging the signal.

+ Repeat the test through the complete operating range.

EXPECTED

✓ Output matches this construction type

✓ Stable levels and repeatable response

✓ Agreement with related scan data

COMMON FAULTS

— Incorrect test method for the sensor type

— Supply, ground or signal-circuit fault

— Installation, target or calibration concern

Correct theory and operation

HOW IT
WORKS.

Understand the sensing method, circuit and controller strategy before interpreting data or replacing the component.

01

Measured condition

Estimates seat occupancy and loading for restraint deployment decisions.

02

Signal type

Digital networked sensor. Internal electronics condition the sensing element and transmit calculated data through a dedicated digital line or vehicle network.

03

Controller use

The receiving controller checks range, rationality and rate of change against related inputs before setting a fault or substituting a value.

04

Installation matters

Mounting, target condition, air gap, contamination, temperature, shielding or calibration may affect the result even when the circuit is intact.

Common mistakes

AVOID THE
FALSE CLUE.

COMPLETE TEST SEQUENCE

  1. Perform a complete module scan before disconnecting anything.
  2. Verify powers, grounds, wake-up and communication.
  3. Compare the sensor PID with related physical measurements.
  4. Follow calibration, initialization and replacement procedures.
  5. Repeat the original operating condition and confirm the repair.
DO NOT CONDEMN THE SENSOR

Prove its supply, ground, signal path, physical input and calibration before replacement. Vehicle-specific specifications always win.

SENSOR LIBRARYReturn to all sensors→