Analog MAP
5 V reference, low reference and signal
Pressure is represented by a ratiometric voltage, commonly higher near atmospheric pressure.
Reading the signal
Good waveform
The measured signal changes consistently with the physical input and stays within the application-specific operating range. Under a steady input, it should remain stable apart from normal noise or control activity.
Faulty waveform
Dropouts, unexpected spikes, a signal pinned near a supply rail, or a biased reading can indicate a problem. Verify the real input, reference and loaded ground before blaming the sensor; a smooth signal can still be inaccurate.
+ Verify 5 V and low reference under load.
+ Compare KOEO pressure with barometric pressure.
+ Apply measured vacuum and watch for a smooth voltage change.
✓ Smooth transfer curve
✓ Repeatable return to barometric
✓ No hysteresis or flat spots
— Biased reference
— Blocked port
— Signal dropout